Spindle gas seal gas flow. Spindle static state pulse (µm).
Motor windings Pressure test (V/M). 1500V/1 minute withstanding Voltage test. For castings, aluminum, glass, etc. The system must ensure that the cooling water temperature of supply spindle is between 24-28 degree.
Usually setting the flow switch in return pipe of the cooling system, to ensure the supply of spindle cooling water. In order to prevent water or impurities enters internal of the spindle, spindle will have gas sealing device, the gas seal machine must be started start with the machine at the same time. And the need to go through multi-stage filtration. The quality requirement of gas which is used in gas seals: Oil content. Only all monitoring issued no failures operational signals, at the same time, all safety devices have been installed and working properly, then allow start spindle.Note: new or spindle which is not used for a long time must to be running slowly. First, start run spindle for half an hour as 25% of the maximum speed, then increase to 50% of the maximum speed, to run 15 minutes, finally, increase to maximum speed.
It's need to check the temperature of the spindle during the whole process, spindle will get hot, but not hot hand, if the spindle becomes hot, pls stop the operation and contact our customer service department. Please note that when stopping the spindle, you need to wait until the spindle is stopped before using the tool, so as to avoid causing the spindle and the tool mechanism to be connected together and cannot be separated.
When loosening the tool and broaching the tool, you need to return the air, and pls keep the air intake and return air during the whole work. 380V input with 380V output. Key word: VS500 series inverter. Relying on its superior costefficiency, VS500 series general inverter is widely.
Applied in the industry of machine tool, electricity, textile, transportation, transmission. The series product has been developed to be model in high stability, reliability after on-site inspection of. More than 700,000 inverters.Compact yet reasonable structure reduces the volume of inverter 20%-30% times than the traditional general inverter; independent cooling duct and closed main loop design. Droop control function: automatically balance power of drive system of inverters on the same transmission chain. Adopts DC fan characterized by the large volume, high wind pressure, excellent cooling.
Particular self-adaptive control technology, allowing for automatic current and voltage limitation and under-voltage suppression during operation. Standard configuration of RS485 communication interface, optional MODBUS protocol and SUNFAR self-defined protocol; with linkage synchronous control function, allowing for easily communicating inverters with PLC. Industrial personal computers and other industrial personal equipments. BT30-ER25 tool holder with 45° pull stud. The 3.7KW VFD Inverter.